Readeagle3096 ARIES-2200 Factory Price High Quality Anesthesia Equipment Vet Anaesthesia Instruments for Pet Hospital

  • FOB Price:US $4999-7999 / Piece(s)
  • Min.Order:1 Piece(s)
  • Production Capacity:5000 unit per years
  • Payment Terms:L/C , T/T , D/P , Western Union , D/A
  • Favorite
Beijing Read Eagle Technology Company

Business Type:Manufacturer

Country/Region:China

Ddu Verified

HOT Rank

8/10

Product Information

  • Certification:CE
  • Dimension:73cm x 80cm x 153cm
  • Packaging Details:carton,wooden case
  • Brand Name:READ EAGLE
  • Place of Origin:China(mainland)
  • Warranty:1 year

Description

Respiration mode

IPPV, SIMV, SIGN, MANUAL, STANDBY, DEMO

I:E ratio

8:1~1:8

Tidal Volume

50ml~1600ml

Respiratory frequency

1~65bpm

PEEP

mechanical

Waveform

P-t, F-t

Patient type

Adult,Pediatric

Display

10.4 TFT color screen

Driven mode

Pneumatically Driven

Electronically Controlled

Pressure Setting

1-60cm H2O

Trigger Pressure

-20-20CM H2O

Inspiration Plateau

0-55%Ti

Working mode

Semi-Open/Semi-closed/Closed system

Gas Supply Pressure

O2:0.27Mpa-0.55Mpa

N2O:0.27Mpa-0.55Mpa

Special Feature

 

1) 10.4" TFT screen (Sharp brand), all parameters are clearly showed.

2) Metal frame, with plastic spray, durable and lasting.

3) Double vaporizer station, selectatec compatible.

4)Classical Flowmeter of 4 tubes, with O2/N2O linkage device.

5) Could be easily upgraded with functions: eg adding Multi-parameter Monitor, CO2 Monitor, AMIS System

6)Use advanced differential pressure sensor (Honeywell brand) to monitor tidal volume, the sensor probe is built inside the absorber, so as to avoid the affect of water vapor on tidal volume and improve the accuracy.

Safety Function
·When airway pressure reach 6kPa, APL valve will automatically release gas.
·When airway pressure reach 6kPa, the Bellows will stop sending gas to patient.
·Alarm parameters (Audible and/or visual signal):
1)Airway Pressure high / low limit
2)FiO2 high/low limit
3)Minute Ventilation Alarm
4)Low O2 Supply Pressure(when O2 Supply Pressure is lower than 0.15Mpa, will arouse Audible Alarm)
5)N2O automatic Cutoff Alarm
·Monitoring parameters (Under Manual and Ventilation):
Tidal Volume / Respiratory Frequency
Minute ventilation / Airway Pressure
Inspiration Plateau / Respiration mode / FiO2
Electrical Specification
·Mains: 100-240V, 50/60Hz
·Battery: 12V DC, minimum 120 min.(if with)
·Power consumption: ≤50W
Optional
·Patient Monitor
·York Device
·CO2 Monitor 
·AGSS
·AMIS
·Circle absorber heating function